general data | |
---|---|
mounting type | flush |
special type | linearized |
type | distance measuring |
measuring distance Sd | 0 … 6 mm |
resolution | < 0,003 mm (High Accuracy Mode) |
repeat accuracy | < 0,01 mm |
adjustment | IO-Link |
teach | Single point, Two point, Window |
linearity error | Single point, Two point, Window± 25 µmИли отправьте нам запрос на µm (S = 0 ... 6 mm) |
temperature drift | Single point, Two point, Window± 25 µmИли отправьте нам запрос на µm (S = 0 ... 6 mm) ± 2 % (Full Scale; S = 0 ... 4 mm) ± 3 % (Full Scale; S = 0 ... 6 mm) |
hysteresis | < 99 % (adjustable) |
power on indication | LED green |
output indicator | LED yellow |
electrical data | |
response time (factory characteristic) | < 1 ms |
switching frequency | < 1 kHz |
voltage supply range +Vs | 8 … 36 VDC |
current consumption max. (no load) | 15 mA |
output circuit | push-pull / IO-Link |
output current | < 100 mA |
short circuit protection | yes |
reverse polarity protection | yes |
communications interface | |
interface | IO-Link V1.1 |
baud rate | 230,4 kBaud (COM 3) |
cycle time | ≥ 0,6 ms |
process data length | 32 Bit |
process data structure | 32 BitBit 0 = SSC1 (distance) Bit 1 = SSC2 (distance) Bit 3 = alarm Bit 4 = SSC3 (frequency) Bit 5 = SSC4 (counter) Bit 16-31 = 16 Bit measurement |
IO-Link port type | Class A |
adjustable parameters | Class Ameasuring range switching point switching hysteresis measured value filtering time filters LED status indicators output logic output circuit counter deactivate the sensor element Find Me function |
additional data | Class Ameasuring range switching point switching hysteresis measured value filtering time filters LED status indicators output logic output circuit counter deactivate the sensor element Find Me functiondistance frequency operating cycles operating hours boot cycles operating voltage device temperature histograms |
mechanical data | |
type | cylindrical threaded |
housing material | brass nickel plated |
dimension | 12 mm |
housing length | 50 mm |
connection types | connector M12 |
tightening torque max. | 15 Nm (A: 10 Nm) |
ambient conditions | |
operating temperature | -25 … +75 °C |
protection class | IP 67 |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |